Owner’s Manual Keep with machine for reference MODEL CMA-180UC INSTALLATION & OPERATION Rev 1.15B 800-854-6417 FAX 714-895-214
Brown (LIVE) wire Multi-conductor cable Black (Main Power) Note: Machine Neutral(White wires) Detergent Signal wires (Red terminals) Rinse Signal
2.2.5. Safe Ttemp Feature The CMA “SafeTtemp” feature assures the final rinse cycle is always at a consistent minimum of 180 degrees. How it works:
2.2.6. Water Tempering Kit MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.15B Page 11
2.2.7. Booster Heater Setup The booster tank must be filled with water before the heating element is energized. For this reason the “High Limit Swi
Operation 3. Operation 3.1. Initial Setup 3.1.1. Dema Valve and Dema Flow Disc (New Models). New Dema Valve made of stainless steel is more compat
Operation 3.3. Operating and Cleaning Instructions MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1
Operation 3.4. Preventive Maintenance Chart MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.15B Page 15
Operation 3.5. Quick service guide MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.15B Page 16MODEL: CMA 180UC HIGH TEMP UNDER COUNTER
Operation 3.6. Troubleshooting PROBLEM LIKELY CAUSE SOLUTION Power off at circuit breaker Reset circuit breaker Machine inoperative Defective powe
Operation PROBLEM LIKELY CAUSE SOLUTION Turn up supply water heater Low incoming water temperature (below 140° F) Insulate supply water pipe Thermos
TABLE OF CONTENTS MODEL CMA-180UC 1. SPECIFICATIONS ... 2 1.1.
Operation PROBLEM LIKELY CAUSE SOLUTION Start switch requires > 1 second activation to run cycle Defective (Instant Start) ice cube relay Replace
4. Parts Kit 4.1. Initial Parts Kit (P/N 1100.66) P/N DESCRIPTION Qty 15504.00 Motor Contactor, 2-Pole 20 Amp 1 15504.50 Heater Contactor, 2-
Parts Manual 4.2. Optional Drain Pump Kit ITEM NO. NO. REQ’D P/N DESCRIPTION ITEM NO. NO. REQ’DP/N DESCRIPTION 1 1 15503.00 Drain Motor Ult
Parts Manual 4.3. Optional Drain Pump—INSTALLATION INSTRUCTIONS 1. Start by removing the existing drain hose from the Drain Valve as shown in Fig
Parts Manual Secure the drain gooseneck to the wash riser pipe with the hose clamp provided as shown in Figure 3. 5. Secure with hose clamp Figur
5. Customer Notice CMA-180UC Installation Guidelines Improper installation of this product may void the warranty on this machine. Please follow th
Electrical Diagram Electrical Diagram 6. Electrical Diagram 6. Electrical Diagram MODEL CMA-180UC INSTALLATION & OPER
Electrical Diagram MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.15B Page 26
1. Specifications METRIC EQUIVALENT 1.1. CMA-180UC WATER CONSUMPTION PER RACK .86 GAL. (3.25 L) PER HOUR 20.6 GAL. (77.8 L) OPERATING CYCLE
1.2. CMA-180UC Operational Cycle The CMA-180UC Operational Cycle has a total cycle time of 2 minutes (120 seconds). The Timing Diagram and the ste
5. When the cam timer assembly approaches the final rinse portion of the cycle, the “Safe-T-Temp” sixth micro switch will pause cam timer assembly i
Getting Started 2. Getting Started 2.1. Introduction to CMA-180UC The CMA-180UC is a hot water sanitizing, single rack, under-counter dishmachine.
2.2. Receiving and Installation The dishwasher is shipped from the factory in a corrugated box on a wooden pallet. The installation guidelines give
2.2.3. BETA Detergent And Rinse Dispenser (Optional). Optional built-in Beta dispenser (CMA p/n 14585.00) has easy access for chemical settings
2.2.4. NOVA Detergent and Rinse Dispenser (Optional)1. The NOVA Detergent and Rinse Dispenser has its own reference manual. Familiarize yourself wi